Ceiling Mounted Fire Alarm Strobes

Wall mounted fire strobes must be placed 80 to 96 inches above the floor and at least six inches from the ceiling in all non sleeping areas.
Ceiling mounted fire alarm strobes. This calculator uses data provided by the user to perform the calculations described in nfpa 72 2002 2007 2010 and 2013 edition which permits the use of a performance based alternative in lieu of tables for spacing ceiling mounted audible visible devices. See 18 5 4 1 and 18 5 4 2 and for ceiling mounted strobes no more than 30 ft. The world s first dual cell photoelectric smoke alarm. Ceiling mounted fire strobes should not be more than 30 feet above the floor.
The strobe is always located in the center of the coverage area. Corridor spacing of visible signals can be applied if the corridor width is no more than 20 feet wide. Our team had long recognized a need for better smoke detection. Strobes feature field selectable candela settings and are compatible with 12 or.
1609 park 370 place saint louis mo 63042. System sensor is a global manufacturer of fire and life safety devices in smoke detection carbon. The code also allows ceiling mounted strobes to be used for compliance and has a separate table providing the relationship of room size and ceiling height to determine the effective intensity of the strobes in that application. Low ceiling heights do not permit mounting at a minimum of 80 inches visible appliances shall be mounted within 6 inches of the ceiling.
5757 phantom drive suite 125 saint louis mo 63042. Refer to the annex of nfpa 72 for exceptions to these guidelines a 18 5 4 3. In a sleek modern design the wheelock exceder strobes feature high efficiency optics to minimize current draw. 6 where the ceiling strobe is not located in the center of the room the candela level shall be determined by doubling the.
If the ceilings are higher than 30 feet the strobes must be mounted on the wall. In 1974 a product was introduced that literally revolutionized the industry. Except where an existing fire alarm system is upgraded or replaced or a new fire alarm system is installed the adaag goes on to. A plan view of a ceiling mounted fire alarm notification device s coverage area shows that the coverage projects outward along the strobe s mounting surface at an equal distance on all sides creating the square coverage areas listed in nfpa 72.
Ceiling mount or wall mount varieties to meet a wide variety of applications are ideal for warning hearing impaired individuals during an emergency event.